5E-AC/PL calorimeter is used to determine the calorific value of solid and liquid combustibles such as oil, coal, coke, foodstuffs and biomass products, which is widely applied in power plant, coal mine, metallurgy, chemical industry, commercial inspection, scientific research, etc.
Please leave your E-mail address before download the product PDF. Your cooperation is appreciated.
Warm prompt: Please make sure you entered a correct E-mail address. We will send you relevant information and product quotation regularly.
Standard Configuration:
Main analyzer Standard CV bomb Computer Handle Oxygen Charger Crucibles Ignition Wire Benzoic Acid O-ring kit Tool kit |
Optional Configuration:
Lens paper Pellet press& Bench-top oxygen charger Halogen Resistant Oxygen Vessel
|
Features:1. Water cycling system applies the theory of communicating vessels, simple and reliable.
2. Large jacket volume minimizes the heat transfer between bucket and the environment.
3. Large water tank is equipped for cooling down water from the bucket after each analysis.
4. Auto-diagnosis, remote data transfer and balance connection available.
Model | 5E-AC/PL Calorimeter | |
Conforms to Method | AS 1038.5, ASTM D5865, ASTM D4809, ASTM E711, BIS 1350, BS EN 15400, GB/T213, GB/T30727, ISO1928, ISO9831, ISO 18125, ASTM D240 | |
Measuring range | Up to 50000J | |
Temp.Resolution | 0.0001℃ | |
Control Ability | 2 Units/ 1 PC available | |
Analysis Time per Sample | Dynamic method:about 11mins; Classical Method: about 16mins | |
Jacket Type | Isoperibol | |
Vessel Identification | Up to 2 for automatic, several for manual | |
Balance Connection | Available | |
Network Connection | Available | |
Bucket Filling | Automatic | |
Oxygen Filling | Semi-Automatic | |
Structure | Vertical | |
Bomb Vessel Lifting | Manual | |
Power Supply | Single phase, AC220V±10%, 50/60Hz,≤500W | |
Net Weight | 75kg | |
Dimensions(L×W×H) | Vertical: 580mm×550mm×950mm | |
* Test Condition: 1. Ambient temp.20℃±1℃,humidity75%±5% 2. No strong interference source nearby 3.Clean water circuit with distilled water 4. Refer to the precision of ten acceptable calibration test runs |
Handle oxygen charger
Bench-top oxygen charger
Guide pipe components
Oxygen vessel
Bomb lift
Mainboard
Ignition board
Control panel
Temperature measuring board
Probe (Bucket)
Magnetic pump
O-ring-12×3
O-ring-18×2.4
O-ring-12×2
O-ring-16×2.65
O-ring-60×5.7
O-ring-6×1.9
O-ring (Bucket)
Crucible holder
Exhaust valve
Wipe cloth
Oxygen bomb holder
Pressing machine
Crucible
Ignition wire
Serial wire with magnetic ring
Benzoic acid
Standard coal sample
Pressure reducing valve
Magnetic pump
Ignition electrode assembly
Suspender II
Suspender I
Crucible
Lens paper